pg1_pg20.FH10 - page 214

212
Fire Alarm Systems
Order Code
SYS-7101
SYS-7102
SYS-7104
BAT-3002
Description
2 Zone FIREpro Control Panel
4 Zone FIREpro Control Panel
8 Zone FIREpro Control Panel
3.4A Batteries
(x 2 Required)
Order Code
SDR-3001
AV-1009
Description
Roshini Sounder
Solista Sounder / Beacon
Sounders / Beacons
Order Code
CP-1000
CP-1001
CP-1003
Description
Universal Callpoint
Callpoint Glass (pack of 10)
Callpoint Protective Cover
Call Points
Order Code
BEL-1015
Description
6 Inch Red Bell
Bells
FIREpro Conventional System
The FirePro control panel is housed in the most attractive,
modern designed, flame retardent ABS enclosure, utilising a
switch mode power supply. It has a fully removable front cover
which improves ease of access for cable installations.
Access via password – removes problem of lost keys
One man test facility
Disablement facility for zones & sounders
Space for up to 3.4Ah batteries
Sounder delay option
4 sounder circuits (4 Zone & 8 Zone)
Sounder circuits 3 and/or 4 can be configured as Aux
24V supplies
Meets all requirements of latest EN54 part 2 & part 4
Features:
Order Code
SD-6000
SD-6002
SD-6004
SD-6005
SD-6007
SD-6009
SD-6011
Description
Optical Smoke Detector + Sounder + Beacon
Heat Detector A1 + Sounder + Beacon
Optical Smoke Detector + Sounder
Heat Detector A1 + Sounder
Optical Smoke Detector
Heat Detector A1
Detector Base
Detectors
Order Code
AS-3000
AS-3001
AS-3002
SD-6013
BAT-3002
Description
2 Zone Pulse Control Panel
4 Zone Pulse Control Panel
8 Zone Pulse Control Panel
Relay Module (1A 30V)
3.4A Batteries
(x 2 Required)
Order Code
SD-6014
SD-6015
SD-6018
SD-6019
SD-6020
Description
Sounder Base
Sounder / Beacon Base
Open Area Sounder
Open Area Sounder / Beacon
Open Area Beacon
Sounders
Order Code
SD-6022
AD-2070
Description
Callpoint
Callpoint Protective Cover
Call Points
The new Pulse2 AlarmSense® range consists of a series
of conventional, 2, 4 and 8 zone fire alarm control panels
designed and approved in accordance with European
standards BS EN54-2 and BS EN54-4 Fire Detection and
Fire Alarm systems - Control and Indicating Equipment.
The AlarmSense® system enables all devices in a given
zone to be wired to the same pair of cables thus greatly
reducing the cabling and installation requirements and
hence costs.
The AlarmSense® range of devices includes smoke and
heat detectors, call points, base sounders, base
sounder/beacons and relay units - all wired to the same
pair of cables.
Having sounders and sounder beacons installed on the
same cabling as detectors and call points allows all systems
to be configured for common, zonal or two stage alarm by
simply setting one of the panels configuration options.
Selection of theAlarmSense® local alarm feature at sounder
or sounder beacon bases invokes the alarm verification
feature. This is particularly useful in Houses of Multiple
Occupation such as student accommodation or nursing
homes. When sounder or sounder beacon bases are
selected for local alarm mode, any alarm sounders are
restricted such that only the sounder connected to the
activated detector will operate initially. The panel will attempt
to reset the activated detector after a time delay and if
successful no further alarms are sounded. If the detector
re-activates after being reset, a general alarm will sound
throughout the premises. Activation of a second detector
or a call point will sound the general alarm immediately.
Product Overview:
AlarmSense
®
Bi-Wire System
Fully certified to BS EN54-2 and BS EN54-4
Allows systems to be installed in accordance with
BS5838: Part 6
2 wire systems, reduces installation cabling
2-wire repeaters and ancillary boards via serial bus
Fully programmable using simple menu options
Adjustable sounder delay time
Sounder configuration options
Zonal sounder delay for detectors only
Zonal sounder delay for call points only
Coincidence output via ancillary board
Short circuit fire selectable by zone
Non latching selection by zone
Silent zones (common sounder outputs)
Zone input delay for sprinkler system connection
AlarmSense® local alarm feature supported
Simple, single board construction
Installer friendly
Compatible with all AlarmSense® devices
Two conventional monitored sounder outputs
3 Amp power supply
Auxiliary power output
Features:
Order Code
AV-1040
SBE-2003
SBE-2002
Description
Wall Sounder / Beacon - Red Body, White Flash
Wall Beacon - Red Body, White Flash
Ceiling Beacon - White Body, White Flash
Now Available, New EN54-23 Visual Alarm Devices (VAD’s).
Further options available upon request.
SYS-7105
SYS-7107
SDR-3001
BEL-1015
CP-1000
SBE-2002
AV-1040
SD-6022
SD-6007
SD-6000
SD-6005
SD-6018
Order Code
SYS-7105
SYS-7106
SYS-7107
SYS-7108
SYS-7109
Description
Optical Smoke Detector
Rate-of-Rise Heat Detector
Fixed Temperature Heat Detector
Opto-Heat Detector
Diode Base
Detectors
1...,204,205,206,207,208,209,210,211,212,213 215,216,217,218,219,220,221,222,223,224,...324
Powered by FlippingBook