pg1_pg20.FH10 - page 215

213
Fire Alarm Systems
4 line x 20 character LCD display
Ability to differentiate between callpoint or detector alarms
Checkpoint alarm verification feature
Available in 2, 4, and 8 zone panel versions
Highlighted selection menu
Event log storing up to 500 events
3 enhanced test modes
Allows detectors and sounders to be installed on the same
pair of wires
Up to 32 devices per zone
Built-in EOL capability in all devices
7 modes of detection
TWINFLEXpro Bi-Wire System
This versatile fire alarm panel incorporates Fike’s Multipoint
detection system using smoke and heat detectors with built-
in sounder, allowing the whole system to be installed using
only one pair of wires per zone.
Using the Multipoint detector with sounder as part of the
TWINFLEXpro 2-wire fire alarm system means that when a
detector is wired in, a sounder is also, with no extra wiring
required. This greatly reduces the number of points that need
to be installed - and the time it takes to install!
Order Code
FC-3035
FC-3036
FC-3037
BAT-3002
Description
2 Zone TWINFLEXpro Control Panel
4 Zone TWINFLEXpro Control Panel
8 Zone TWINFLEXpro Control Panel
3.4A Batteries
(x 2 Required)
Order Code
FC-3047
FC-3046
Description
ASD Multi-Point Detector + Sounder
ASD Multi-Point Detector
Detectors
Order Code
FC-3034
FC-3026
Description
Callpoint - Resettable
Callpoint Cover
Call Points
Order Code
FC-3017
FC-3019
Description
Red Hatari Sounder
Flashpoint Sounder / LED Beacon
Sounders
1, 2, or 4 loop formats
Up to 254 devices per loop (Protocol dependent)
Up to 1,000 fire detection zones
Up to 188,800 devices per network
True peer-to-peer networking
Networkable up to 200 nodes
Supports intelligent / programmable remote terminals,
BMS interface, IP Gateway and I/O Drivers
Circuit monitoring of local panel circuits
Autolearn and Loop Detection
Simple Select & Click programming
1,000 event log entries
Simplified logic delivers click and go configuration
Built in voltage and current meters
Quick start and protect - a working system after an
Autolearn is performed
Single area false alarm management facility
Optional Peripheral Expansion Card
Programmable logo on screen
Compatible with Apollo Discovery and XP95, Argus Vega,
Hochiki ESP and Nittan Evolution protocols
Approved to EN54 parts 2 and 4
Features:
Addressable Fire Alarm System
Order Code
AP-1000
AP-1014
AP-1019
ADI-2002
Description
1 Loop Panel
2 Loop Panel
4 Loop Panel
Input / Output Interface (1A 30V)
Order Code
AD-2000
AD-2002
AD-2005
Description
Optical Smoke Detector
Heat Detector
Detector Base
Detectors
Order Code
AD-2016
AD-2018
AD-2037
AD-2038
AD-2031
Description
Sounder Base + Isolator
Sounder / Beacon Base + Isolator
Wall Sounder + Isolator
Wall Sounder / Beacon + Isolator
Wall Beacon + Isolator
Sounders
FC-3047
FC-3017
FC-3034
AD-2000
AD-2016
AD-2038
AD-2068
Order Code
AD-2068
AD-2070
Description
Callpoint + Isolator
Callpoint Protective Cover
Call Points