pg1_pg20.FH10 - page 226

224
Contactors
TeSys Model K Contactors
3 Pole Contactors 6-12A/AC3
(Control coils included)
Order Code
LC1K0601**
LC1K0610**
LC1K0901**
LC1K0910**
LC1K1201**
LC1K1210**
3Ph/400V
(kW)
2.2
2.2
4
4
5.5
5.5
See table below for AC coil or DC coil suffix.
AC-3
(A)
6
6
9
9
12
12
NO
-
1
-
1
-
1
NC
1
-
1
-
1
-
Auxiliary
K-Range Auxiliary Blocks
Order Code
LA1KN11
LA1KN20
LA1KN22
Contacts
1 NO + 1 NC
2 NO
2 NO + 2 NC
D-Range Auxiliary Blocks
Order Code
LADN01
LADN10
LADN22
LADN40
LADN04
Contacts
1 NC
1 NO
2 NO + 2 NC
4 NO
4 NC
TeSys Model D Contactors
Coil Voltages
Add the suffix below to the contactor reference to specify control voltage required
AC Supply
Coil Ref (Last 2 Digits)
DC Supply
Coil Ref (Last 2 Digits)
12
J7
12
JD
24
B7
24
BD
42
C7
110
FD
48
E7
110
F7
230
P7
380
Q7
400
V7
Overload Relays
TeSys Model K
Thermal Overload Relays
Class 10A Differential Bi-metallic Thermal
Overload Relay
Order Code
LR2K0303
LR2K0304
LR2K0305
LR2K0306
LR2K0307
LR2K0308
LR2K0310
LR2K0312
LR2K0314
LR2K0316
Setting Range Amps
0.23 ... 0.36
0.36 ... 0.54
0.54 ... 0.8
0.8 ... 1.2
1.2 ... 1.8
1.8 ... 2.6
2.6 ... 3.7
3.7 ... 5.5
5.5 ... 8.0
8.0 ... 11.5
LRD Accessories
Order Code
LAD7B106
LAD73064
For Use With
LRD01 ... LRD35
LRD33**
Separate Mounting Base for overload relays.
TeSys Model LRD
TeSys Model LR2K
3 Pole Contactors 9-150A/AC-3
(Control coils included)
Order Code
LC1D09**
LC1D12**
LC1D18**
LC1D25**
LC1D32**
LC1D38**
LC1D40A
LC1D50A
LC1D65A
LC1D80**
LC1D95**
LC1D115**
LC1D150**
3Ph/400V
(kW)
4
5.5
7.5
11
15
18.5
18.5
22
30
37
45
55
75
See table below for AC coil or DC coil suffix.
AC-3
(A)
9
12
18
25
32
38
40
50
65
80
95
115
150
NO
1
1
1
1
1
1
1
1
1
1
1
1
1
NC
1
1
1
1
1
1
1
1
1
1
1
1
1
Auxiliary
Class 10A Differential Bi-metallic
Thermal Overload Relay
Order Code
LRD05
LRD06
LRD07
LRD08
LRD10
LRD12
LRD14
LRD16
LRD21
LRD22
LRD32
LRD35
LRD340
LRD350
LRD365
LRD3322
LRD3353
LRD3355
LRD3357
LRD3359
LRD3361
LRD3363
LRD3365
Setting Range Amps
0.63 ... 1.0
1.0 ... 1.7
1.6 ... 2.5
2.5 ... 4.0
4.0 ... 6.3
5.5 ... 8.0
7.0 ... 10.0
9.0 ... 13.0
12.0 ... 18.0
16.0 ... 24.0
23.0 ... 32.0
30.0 ... 38.0
30.0 ... 40.0
37.0 ... 50.0
48.0 ... 65.0
17.0 ... 25.0
23.0 ... 32.0
30.0 ... 40.0
37.0 ... 50.0
48.0 ... 65.0
55.0 ... 70.0
63.0 ... 80.0
80.0 ... 104.0
TeSys Model D
Thermal Overload Relays
For Use with
Contactor LC1
D09 ... D38
D09 ... D38
D09 ... D38
D09 ... D38
D09 ... D38
D09 ... D38
D09 ... D38
D12 ... D38
D18 ... D38
D25 ... D38
D12 ... D38
D32 + D38
D40A ... D65A
D40A ... D65A
D50A + D65A
D80 + D95
D80 + D95
D80 + D95
D80 + D95
D80 + D95
D80 + D95
D80 + D95
D80 + D95
1...,216,217,218,219,220,221,222,223,224,225 227,228,229,230,231,232,233,234,235,236,...324
Powered by FlippingBook