pg1_pg20.FH10 - page 284

282
Switch Fuses
Glasgow Switch Fuses
& Switch-Disconnectors
Five frame sizes are available to provide a range from 63A to 800A, with utilisation category
AC22A and AC23A Ue 415V ratings.
All units have retractable operating handles which drive over-centre mechanisms incorporating
powerful operating springs. Flag ‘on-off’ indication is provided and terminal cover shields
prevent contact with live metal.
Surface-mounting enclosures comprise heavy gauge steel body plates incorporating cast
iron frame members and are rust protected, with a light grey paint finish. Front access doors,
which are detachable, are fitted with dust-excluding gaskets and are interlocked to prevent
opening when the switch is ‘on’.
SPSN
61GNC
101GNC
151GNC
201GNC
-
-
-
-
-
Rating
63A
100A
160A
200A
315A
400A
500A
630A
800A
TPN
63GNC
103GNC
153GNC
203GNC
303GNC
403GNC
503GNC
603GNC
803GNC
TPSN
64GC
104GC
154GC
204GC
304GC
404GC
504GC
604GC
804GC
SWITCH
FUSES
SWITCH
DISCONNECTOR
Order Code
63GNL
103GNL
-
203GNL
-
403GNL
-
603GNL
803GNL
All units are supplied with fuselinks or switchlinks fitted. Glasgow switch fuses and switch-
disconnectors are type tested to BSEN60947-3 and meet the constructional requirements
for isolation as specified in BSEN60947-3.
Exel 2 switch disconnectors and switch fuses are type tested to BSEN60947-3 and meet the
constructional requirements for isolation as specified in BSEN60947-3.
Switches are of the quick make and break type, suitable for use on AC or DC. Units have
removable moving contact assemblies to facilitate wiring.
Exel 2 surface-mounting enclosures are fabricated from rust-protected sheet steel with a light
grey paint finish with removable top and bottom endplates incorporating knockouts (blank
endplates available) and gasketed doors giving IP41 protection. Chromium-plated front operating
handles with “ON (I) OFF (O)” indication, and internal fixing enabling units to be mounted closely
side by side. Interiors comprise porcelain bases fitted with non-ferrous conducting components.
Exel 2 Switch Fuses
& Switch-Disconnectors
SPSN
15KXSC2F
30KXSC2F
60KXSC2F
100KXSC2F
-
Rating
20A
32A
63A
100A
125A
DP
15KXDC2F
30KXDC2F
60KXDC2F
100KXDC2F
-
TPN
15KXTNC2F
30KXTNC2F
60KXTNC2F
100KXTNC2F
125KXTNC2F
SWITCH
FUSES
SWITCH
DISCONNECTOR
DP
15AXD2
30AXD2
60AXD2
100AXD2
-
TPN
15AXTN2
30AXTN2
60AXTN2
100AXTN2
125AXTN2
MCCB Panelboards
Memshield 3 MCCB Panelboards
The feature packed Memshield 3 MCCB panelboard distribution system
A complete range of MCCB panelboards and pan assemblies providing all the options you
need from a straightforward panelboard to a comprehensive panelboard system. The range
now offers a variety of incoming devices and a greater choice of outgoing ways to provide
more flexibility and choice to the user.
250A, 400A, 630A & 800A panelboard versions available.
Can be configured for incomer device at top of panelboard.
3 or 4 pole incoming devices can be fitted.
4 to 18 outgoing TP ways.
Outgoing MCCBs up to 400A, available in 25kA, 36kA and 50kA breaking capacity.
All TP MCCBs have adjustable thermal and magnetic trip units as standard. MCCBs with
additional trip unit functionality are available to special order:
- Distribution circuit protection, electronic.
- Motor protection, thermal/magnetic.
- Motor protection, electronic.
- Motor protection without overload release.
- Selective (discriminative) and generator protection, electronic.
IP3X construction.
Form 3b type 2 segregation.
Tin-plated busbar systems throughout the range.
Incoming and outgoing metering options to ensure Part L2 Building Regulations compliance.
Plug-in cabling system provides for faster and error-proof installation.
Reliable & safe operation assured through KEMA testing & certification.
Wide range of extension boxes, metering, surge protection, and earth leakage incomer
options available.
Versatile solution, accommodating different frame size outgoing MCCBs to best match
application needs.
Enhanced safety through fully shrouded incoming devices, to protect against contact
with live parts.
Blanking plates finger protect unused outgoing ways.
Option to remove top and bottom cross rails provides the ability to lay cables into the board
instead of feeding them through the gland plate aperture, resulting in big time savings.
1...,274,275,276,277,278,279,280,281,282,283 285,286,287,288,289,290,291,292,293,294,...324